Main Purpose of Ozone Tester: Ozone tester popular used for rubber and plastic indsutry testing work. Ozone in the atmosphere is rarely the main factors of rubber cracking, ozone tester simulation and strengthening the atmosphere of ozone conditions, the study of the role of ozone on the rubber,
Rapid identification and evaluation of rubber anti-ozone aging performance and anti-ozone agent Protective effect of the method, and then take effective anti-aging measures to improve the service life of rubber products, the reference standard such as: GB : T7762-2003, GB : T2951.21-2008
Principles and Methods for Ozone Tester:
● Test method according to the test methods and standards can be divided into “static” and “dynamic”, static is the sample is stretched after the release of the test chamber to do the test, the dynamic is placed in the test box on the fixture, While doing the test, stretching the measured sample itself is about 5% -45%.
● The ozone tester used for: electrical, electronic products, components, parts and materials in high and low temperature environment, storage, transportation and use of the adaptive test. The ozone tester limited/ prohibits: flammable, explosive, volatile substances test or storage of samples; Test or storage of corrosive substances; Test or storage of biological samples; Test or storage of samples of strong electromagnetic emission sources

Product Name: | Ozone Tester, Concentration: 10~500ppm |
Product Model: | WEW-OZ-150L-Dynamic |
Volume: | 150 Liters |
Testing Room: | 500*500*600 (W*D*H mm) |
External Dimension: | 900*1000*1700 (W*D*H mm) |
Gross Weight: | 225 Kgs |
Power Supply: | AC 220 +-5%/ 50 +- 0.5Hz |
Main Technical Parameters | Temperature range | 10C ~ 70C | Temperature fluctuation | +- 0.5C; (Volatility: ± 0.5 ℃; Uniformity: ± 2 ℃) | Temperature distribution accuracy | +- 2.0C | Humidity range | 30% ~ 75% RH (Adjustable) | Humidity fluctuation | +- 3% | Humidity distribution accuracy | +- 3% | Ozone concentration accuracy | 10 ~ 500 ppm +-10% | Air flow speed | 12 ~ 16 mm/s | Shelf rotation rate | 360 degree rotating sample rack (adjustable speed) | Pull up frequency | 0-30HZ | Pump speed | 20L/min | Test gas flow | 4.7~10L/min or 280-560L/H | Ozone generator | Single Phase, 220V/ 230V | Ozone exhaust port concentration requirements (optional) | Due to the strong oxidizing and micro-toxicity of ozone, ozone should be discharged into the atmosphere at 0.16PPM to prevent environmental pollution. | Ozone absorber (optional) | Used to adsorb ozone and decomposition, reduce ozone, ozone exhaust destroyers using carefully developed rare metal oxide sintering, not afraid of water, in the process, | Their own produce a certain amount of heat to accelerate the decomposition of ozone. Per kilogram of catalyst can handle up to 1kg of ozone gas, even 150mg / l high concentrations of ozone gas can easily break down into oxygen. |
|
|

Structure | Material: | (A) Inner box: SUS304 stainless steel plate | (B) Outer case: paint (beige) or SUS-304 stainless steel plate | (C) Insulation for Testing Room & Door: rigid polyurethane foam + aluminum silicate insulation cotton double protection. |
| Doors: | (A) Open the door, turn left. window frame / door frame two silicone rubber seal and anti-condensation electric device. Explosion-proof handle; Door hinge: SUS # 304 | (B) Doors and windows with observation window above W300xH450 mm, Box light PL lamp 11W; Testing hole: φ50mm, 1 pc |
| Shelf / Jig requirements | (A) At both ends of the test specimen to be contacted with ozonized air, the test direction of the specimen shall be substantially parallel to the direction of the airflow; Shell, electronic components, ozone generator, these are major components; | (B) The fixture should be made of a material that is not easily decomposable to ozone (eg aluminum). Equipped with round stainless steel rods of different diameters; | (C) the sample rotation speed between (20 ~ 25) mm / s, in a vertical dry air flow in the plane, each sample at the same time to maintain a fixed rate of rise. | (D) The same specimen is rotated for a week (8 ~ 12) min. The scanning area of the specimen is at least 40% of the effective area of the Ozone Tester. | (E) Specimen preparation shall comply with the requirements of GB / T 9865.1. The sample is best cut from the new mold out of the test piece, if necessary, can be cut from the finished product. Samples should be at least 3 samples per test condition. The length of the standard specimen is not less than 10mm, the thickness of 2.0 mm disabilities 0.2mm, the length of the specimen before the two ends of the specimen is not less than 40mm. |
| Control Panel: | (A) Controller display | (B) Power switch | (C) Fault alarm; Ozone Testers | (D) Rotating and pulling up the governor |
| Ozone Tester configuration: | (A) With a stainless steel SUS # 304 rack turntable one | (B) φ50mm lead hole lead hole: 1, and with a hole cover and silicone rubber plug. | (C) 4 casters only for Ozone Tester | (D) Horizontal fixed tripod 4 only | (E) There is a drain hole in the rear of the box to facilitate the condensate drain of the unit; (diameter 8% | (F) Three-phase five-wire system (four-core cable + protective grounding wire) One cable (2.5 meters long). |
|
|
Air Circulation Adjustment: | Adjustment method | FLOW THROW Air supply mode; Horizontal expansion Vertical heat exchange arc cycle. Ozone Tester | Circulating fans | Power-saving motor + stainless steel extended shaft connection multi-centrifugal circulation fan. |
|
Heating System: | Heater control mod | Fin type heat pipe type stainless steel heater heating. PID regulation, actuator: solid state relay. |
|
Refrigeration System: | How it works | Mechanical cooling / air cooling for Ozone Testers | Control mode | The controller of the control system automatically adjusts the operating conditions of the refrigerator according to the test conditions. Ozone Testers | Compressor | Europe and the United States well – known brands of low – temperature efficient full – (France; Tecumseh) | Evaporator | Multi – stage Automatic Load Capacity Adjustment. (Japan; Heron Palace) | Condenser | Air cooling type condenser (Japan; Shuangling) capacity automatic control of the refrigeration system. | Expansion system | Danfoss expansion valve for ozone test chambers; | Refrigerants | Environmentally friendly refrigerant R404 (ozone depletion index are 0). (United States, DuPont) | Refrigeration process | Nitrogen protection welding, two-stage rotary vane pump vacuum, to ensure that the internal cleaning of the refrigeration system, the bottom of the compressor design water tray, condensate through the rear of the tank drain to the box outside the box. | Cooling accessories | (A) Expansion valve (Danish; DANFOSS) | (B) Solenoid valve (Japan; Omron) | (C) Filters (Danish; DANFOSS); Wewon Ozone Test Chambers Copyrihgt | (D) Pressure controller (Shanghai Feng Shen) | (E) Globe valve (Italy; CASTEL) | (F) Oil separator (Europe and the United States; ALCO) |
|
|

Ozone Detection System: | Ozone generator | Use of voltage silent discharge tube to produce ozone | Ozone generator is the key parts for ozone generate for Ozone Tester |
| Ozone detection transmitter | High-precision ozone detection transmitter, the output signal: 4-20MA current signal, with a high concentration alarm device | Ozone exhaust system | After the completion of the experiment, the ozone in the test chamber was discharged to the outside through a dedicated exhaust fan and duct |
|
Control System: | Sensors | Temperature sensor with platinum DIN PT-100Ω | Controller | Imported from South Korea TEMI5.4 inch color LCD touch-type man-machine interface controller, | Large field of vision screen, with screen lock (LOCK) function. |
| Controller specifications | (A) Accuracy: ± 0.1 ℃ + 1 digit. | (B) Temperature resolution: 0.1. | (C) Each time setting range: 0.1 seconds to 320 hours can be set freely. | (D) Temperature force signal Platinum PT100 type. | (E) P.I.D control parameter setting, P.I.D automatic calculation. |
| Screen display function | (A) The use of graphical control software screen chat, the screen direct touch options: including program settings, curve display, historical data, manual operation, automatic operation, auxiliary settings. | (B) Display the execution status, temperature and time set value, remaining time, and the number of remaining cycles. | (C) With a separate program editing screen, you can enter the temperature, time and the number of cycles. | (D) Temperature program settings to graph curve display, with real-time display program curve execution function. | (E) Display the fault status and explain the troubleshooting method. | (F) The temperature setting (SV) is displayed directly with the actual (PV) value. | (G) Screen can be used for backlight adjustment, the screen display protection function can be set, turn off the settings. Ozone Testers |
| Program capacity and control functions | (A) The production of the program adopt the talk function. | (B) The number of cycles: up to 1-9999 times adjustable. | (C) Available program groups: up to 96 PATTEN (ie 96 test specifications can be set and stored separately) | (D) Each shock time can be set: 0 ~ 540Hour59Min. | (E) Room temperature residence time can be set: 0 ~ 540Hour59Min. | (F) With a power program memory, after the resumption of power automatically and continue to execute the program function. Wewon Ozone Testers Co., Ltd. Copyrihgt | (G) The graphics curve can be displayed in real time when the program is executed. | (H) Has a reservation start and shutdown function. | (I) Has date and time adjustment function. |
|
|

Safety Protection Device: | Cooling protection | (A) Compressor overheat protection switch | (B) Compressor high voltage protection switch | (C) Compressor overcurrent protection switch |
| Heating protection | (A) Heater surface temperature over temperature protection | (B) Heater short circuit, overload protection device |
| Other protection | (A) Circulation motor overheat protection | (B) Condenser fan overheat protection | (C) High temperature, low temperature, over temperature protection | (D) Reverse phase, phase failure protection device, | (E) Total power phase sequence and phase loss protection | (F) Leakage protection; heating humidification dry protection | (G) Overload and short circuit protection; power protection |
|
|
Accessories and Random Information: | Shelf on Ozone Testers | SUS304 stainless steel rack 1 (single layer load 10kg) | Power test hole | Power test hole 1, located in the left side of the box, with a cover and soft plug, size ¢ 50mm × 100mm | Power cord | 1 PC | Drainage | 1 PC | Air supply interface | 1 PC | Moving Casters | 4 PCS | Fixing the foot cup | 4 PCS | Maintenance Manual | 1 PC | Controller Manual | 1 PC | Warranty Card | 1 PC |
|
Equipment Conditions of Use: | Power supply | The power cord is located behind the machine | Water sources | Water supply (requiring users to provide cooling water tower) | Air supply | Interface diameter of 8%, pressure 5 to 8KG | Environmental conditions | Temperature: 5 ℃ ~ 30 ℃ Relative humidity: ≤ 85%; Air pressure: 86kPa ~ 106kPa | Channel requirements | This equipment is heavy. Please pre-consider the installation site aisle and handling methods (see the main technical indicators outside the size and weight) | Site requirements | (A) The ground is flat and well ventilated; there is no strong vibration around the equipment | (B) There is no strong electromagnetic field around the device | (C) There are no flammable, explosive, corrosive substances and dust around the equipment |
|
|
Wewon Environmental Chambers Co., Ltd. as a manufacturer and supply Ozone Tester for abroad partners many years ! The mainly product including : ozone tester, Ozone Testers, ozone ometer, environmental chamber, environmental test chamber, climatic chamber, Ozone Chamber, humidity & temperature chamber.
Many thanks for your reading ! I appreciate it ! Meanwhile, I am glad to know you have the inquiry for ozone tester. The related data as above files mentioned, Hope you like it ! For more details check, Please send us a mail. I am waiting for you there ! Thank you.